Velocity Profiler (300kHz)

Reference Designator
CE09OSSM-RID26-01-ADCPTC000
Start Depth
7
End Depth
7
Location
Near Surface Instrument Frame
Current Status
Not Operational
Class
ADCPT (Velocity Profiler (short range))
Series
ADCPT-C
Science Discipline
Physical
Make
Teledyne RDI
Model
WorkHorse Sentinel 300khz
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CE09OSSM/RID26/01-ADCPTC000/metadata
Method Data Stream Content Type
recovered_host adcp_config Configuration Data Report M2M Engineering
recovered_host adcp_engineering Data Report M2M Engineering
recovered_host adcp_velocity_earth Earth Coordinates Data Report M2M Stats Science
recovered_inst adcp_config Configuration Data Report M2M Engineering
recovered_inst adcp_engineering Data Report M2M Engineering
recovered_inst adcp_velocity_earth Earth Coordinates Data Report M2M Stats Science
telemetered adcp_config Configuration Data Report M2M Engineering
telemetered adcp_engineering Data Report M2M Engineering
telemetered adcp_velocity_earth Earth Coordinates Data Report M2M Stats Science
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 OC1503D 04/09/2015 09/25/2015 CGMCE-09OSSM-00001 CGINS-ADCPTC-17122 46.8539 -124.958 7 542
2 OC1510A 10/15/2015 05/07/2016 CGMCE-09OSSM-00002 CGINS-ADCPTC-22717 46.8531 -124.954 7 542
3 TN-342 05/12/2016 09/22/2016 CGMCE-09OSSM-00003 CGINS-ADCPTC-17122 46.8537 -124.961 7 542
4 AT37-03 09/21/2016 04/14/2017 CGMCE-09OSSM-00004 CGINS-ADCPTC-19002 46.8508 -124.972 7 542
5 SKQ201704S 04/12/2017 10/06/2017 CGMCE-09OSSM-00005 CGINS-ADCPTC-19000 46.8529 -124.959 7 542
6 SKQ201715S 10/04/2017 CGMCE-09OSSM-00006 CGINS-ADCPTC-22809 46.8478 -124.984 7 542
Metadata Start Date End Date Comment
CE09OSSM-RID26-01-ADCPTC000
Deployment: 3
9/6/16 10/22/16

> At roughly 10:30 on Tuesday, the ADCP on the NSIF started to include garbage characters in the data file. It is intermittent, and there are periods where data is still
coming through. This could be a low battery, or something else. In an attempt to remedy it, the voltage supplied to the ADCP has been increased to 24V. This should be checked next week.

The garbage continued to come through after the voltage was changed. CW thinks that it could be a suspect cable, or loose connection, rather than a battery issue. CW will elevate to RedMine.

By Mike Smith, on 10/14/16

CE09OSSM-RID26-01-ADCPTC000
Deployment: 6
Asset: CGINS-ADCPTC-22809
Status: Open Issue
10/6/17 4/2/18

ADCPT started receiving/generating random break commands right after deployment. Interventions at the time were unable to resolve, but we believe the system was collecting data. We reset it and disconnected it from the DCL. Hopefully, it will run autonomously. We presume the problem was caused by the DCL sending erroneous commands, but it could be something else. We’ll see after recovery.

Telemetered data no longer flowing to the system. Data should be available upon recovery.

By Mike Smith, on 12/6/17
Redmine Issue #12979

CE09OSSM
Deployment: 6
Asset: CGMCE-09OSSM-00006
Status: Not Operational
10/11/17 4/2/18

10/11 lost wind turbine 2 (out of 2)
10/24 batteries not recharging sufficiently. To conserve power, the MFN was turned off and the NSIF was reduced to 1 hour communications. The OPTAA is the only instrument on the MFN without internal batteries.
11/8 restored power to entire mooring after a period of strong wind (utilizing WT1)

By Mike Smith, on 12/6/17
Redmine Issue #12980

New Note

No annotations yet.